C7130 Display of the analog input
signals in the InNeg function
block (signal inversion)
313
−32768
(= −199.9 %)
{1} 32767
(= 199.9 %)
1 InNeg−AnV InNeg−AnIn1
2 InNeg−AnV InNeg−AnIn2
C7131 Selection of the analog input
signals for the InNeg function
block (signal inversion)
313
1 InNeg−An 1000 FIXED 0 % (not assigned) Source for InNeg−AnIn1
2 InNeg−An 1000 FIXED 0 % (not assigned) Source for InNeg−AnIn2
For possible signals see "selection list − analog
signals"
437
C7150 Display of the phase input
signals in the InNeg function
block (signal inversion)
313
−2147483647 {1} 2147483647
1 InNeg−PhiV InNeg−PhiIn1
2 InNeg−PhiV InNeg−PhiIn2
C7151 Selection of the phase input
signals for the InNeg function
block (signal inversion)
313
1 InNeg−Phi 1000 FIXED 0 (not assigned) Source for InNeg−PhiIn1
2 InNeg−Phi 1000 FIXED 0 (not assigned) Source for InNeg−PhiIn2
For possible signals see "selection list − phase
signals"
440