Function library
Torque (torque control)
12
348
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C7531] Selection of the signal source for
the analog input signals of the
"Torque" function block
1 TorqueIn−anl 1000 FIXED 0 % (not assigned) Torque setpoint
(SPEED-MCTRL.MAdd)
354
2 TorqueIn−anl 1000 FIXED 0 % (not assigned) Setpoint for the upper limit of
speed limitation
(TORQUE−NSET.NSet)
351
3 TorqueIn−anl 1000 FIXED 0 % (not assigned) Lower torque limit
(TORQUE-MCTRL.negLoMLim)
354
4 TorqueIn−anl 1000 FIXED 0 % (not assigned) Upper torque limit
(TORQUE-MCTRL.HiMLim)
5 TorqueIn−anl 1000 FIXED 0 % (not assigned) Setpoint for the lower limit of
speed limitation
(TORQUE−MCTRL.NStartMLim)
6 TorqueIn−anl 1000 FIXED 0 % (not assigned) Manual field weakening
(TORQUE−MCTRL.FldWeak)
7 TorqueIn−anl 1000 FIXED 0 % (not assigned) Manual adaptation of the
proportional gain of the speed
controller
(TORQUE−MCTRL.NAdapt)
8 TorqueIn−anl 1000 FIXED 0 % (not assigned) Manual adaptation of the
Integral−action component of the
speed controller
(TORQUE−MCTRL.ISet)
9 TorqueIn−anl 1000 FIXED 0 % (not assigned) Torque threshold for the motor
holding brake
(TORQUE−BRK.TorqueThreshold)
360
10 TorqueIn−anl 1000 FIXED 0 % (not assigned) Direction of torque created by
the drive against the motor
holding brake
(TORQUE−BRK.Sign)
For possible signals see "selection list − analog
signals"
437