Code table
13
373
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0134 RFG charac 0
Characteristic of the ramp
function generator for the
l speed setpoint (for "speed
control")
l torque setpoint (for "torque
control")
330
1 Linear Ramp function generator
operates linearly.
2 S−shaped Ramp function generator
operates without jerk (S−shaped).
C0135 Control word 0
System control word DCTRL
0 {1} 65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0 Not assigned
Bit 1 Not assigned
Bit 2 Not assigned
Bit 3 Quick stop (QSP)
Bit 4 Not assigned
Bit 5 Not assigned
Bit 6 Not assigned
Bit 7 Not assigned
Bit 8 Operation inhibit (DISABLE)
Bit 9 Controller inhibit (CINH)
Bit 10 TRIP−SET
Bit 11 TRIP−RESET
Bit 12 Not assigned
Bit 13 Not assigned
Bit 14 Not assigned
Bit 15 Not assigned
C0136 Control words
Hexadecimal value is bit−coded.
Read only
1 CTRLWORD
0 {hex} FFFF
Control word C0135
2 CTRLWORD CAN control word
3 CTRLWORD AIF control word
C0141 FCODE(setval) 0.0
Main setpoint (FCODE_C141_a)
309
−199.99 {0.01 %} 199.99
C0142 Start options 1
Starting condition for start after
l mains connection
l message (t > 0.5 s)
l TRIP
0 Protection against unexpected start−up
1 Automatic start