Appendix
Code table
13
375
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0157 Status of free bits of DCTRL
status word 1 (C0150)
Only display
1 Stat. FreeBit 0 {1 bit} 1 Bit 0 (DCTRL_bStat_B0_b)
2 Stat. FreeBit Bit 2 (DCTRL_bStat_B2_b)
3 Stat. FreeBit Bit 3 (DCTRL_bStat_B3_b)
4 Stat. FreeBit Bit 4 (DCTRL_bStat_B4_b)
5 Stat. FreeBit Bit 5 (DCTRL_bStat_B5_b)
6 Stat. FreeBit Bit 14 (DCTRL_bStat_B14_b)
7 Stat. FreeBit Bit 15 (DCTRL_bStat_B15_b)
C0161 Act trip Current TRIP
l as in C0168/1
l In case of FAIL−QSP, warning,
and message, "0" is displayed.
Only display
238
C0167 Reset failmem 0
Delete history buffer (C0168)
233
0 No reaction
1 Delete history buffer
C0168 Fault history buffer (list of faults
occurred)
Read only
233
238
1 Fail number Currently active fault
2 Fail number Last fault
3 Fail number Last fault but one
4 Fail number Last fault but two
5 Fail number Last fault but three
6 Fail number Last fault but four
7 Fail number Last fault but five
8 Fail number Last fault but six
All fault indications
(TRIP, FAIL−QSP, warning, message)
C0169 Time at which the fault
messages entered in the history
buffer (C0168) occurred.
Read only
233
1 FailTime Respective status of the operating hour counter
(C0179)
Occurrence of the currently
active fault message
2 FailTime Occurrence of the last fault
message
3 FailTime Occurrence of the second−last
fault message
4 FailTime Occurrence of the third−last fault
message
5 FailTime Occurrence of the fourth−last
fault message
6 FailTime Occurrence of the fifth−last fault
message
7 FailTime Occurrence of the sixth−last fault
message
8 FailTime Occurrence of the seventh−last
fault message
0 {1 h} 65535