Appendix
Code table
13
402
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C2357 Monitoring time for XCAN
process data input objects
(AIF interface X1)
Only ECSxA: When the subcodes
1 ... 4 are set, consider the task
runtime:
C2357/1...4 = Desired monitoring
time / task runtime
1 CE monit time 3000 1 {1 ms} 65000 XCAN1_IN monitoring time
2 CE monit time 3000 XCAN2_IN monitoring time
3 CE monit time 3000 XCAN3_IN monitoring time
4 CE monit time 3000 Bus−off
5 CE monit time 3000 AIF monitoring time (can only be
set if C2357/6 = 0)
6 CE monit time 0 Sync monitoring time (can only
be set if C2357/5 = 0)
C2359 AIF HW Set. 0
0 {1} 65535
C2367 Sync Rx Id 128
XCAN receive identifier of the
sync telegram(AIF interface X1)
1 {1} 2047
C2368 Sync Tx Id 128
XCAN send identifier of the sync
telegram
(AIF interface X1)
1 {1} 2047
C2373 XCAN Sync counter
(AIF interface X1)
1 Sync Rate IN 1 1 {1} 240 XCAN1_IN
2 Sync Rate IN 1 XCAN2_IN
3 Sync Rate IN 1 XCAN3_IN
C2374 XCAN Sync counter
(AIF interface X1)
1 Sync Rate OUT 1 1 {1} 240 XCAN1_OUT
2 Sync Rate OUT 1 XCAN2_OUT
3 Sync Rate OUT 1 XCAN3_OUT
C2375 TX mode for XCANx_OUT
(AIF interface X1)
1 XCAN Tx
mode
0 Response to sync XCAN1_OUT
2 XCAN Tx
mode
0 Response to sync XCAN2_OUT
3 XCAN Tx
mode
0 Response to sync XCAN3_OUT
0 Response to sync
1 No response to sync
2 Event
3 Event, cycle C2356 superimposed