Appendix
Code table
13
419
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C6371] Selection of the digital output
signals for the digital output and
the brake relay
308
1 DigoutIn−dig 1000 0 (FALSE, not assigned) Source for the output signal at
the digital output X6/DO1
(DigOut−Out1)
2 DigoutIn−dig 1000 0 (FALSE, not assigned) Source for the control of the
brake relay (DigOut relay)
For possible signals see "selection list − digital
signals"
428
C6430 DFOUT
Display of the analog output
signal DFOut−Out in the DFOUT
function block
304
−32768 {1} 32767
[C6431] DFOUT 1000
Selection of the analog output
signal DFOut−Out for the DFOUT
function block
304
FIXED 0 % (not assigned)
For possible signals see "selection list − analog
signals"
437
C7110 Display of the digital input
signals in the function block
InNeg (signal inversion)
313
1 InNeg−digV InNeg−DigIn1
2 InNeg−digV InNeg−DigIn2
3 InNeg−digV InNeg−DigIn3
C7111 Selection of the digital input
signals for the InNeg function
block (signal inversion)
313
1 InNeg−dig 1000 0 (FALSE, not assigned) Source for InNeg−DigIn1
2 InNeg−dig 1000 0 (FALSE, not assigned) Source for InNeg−DigIn2
3 InNeg−dig 1000 0 (FALSE, not assigned) Source for InNeg−DigIn3
For possible signals see "selection list − digital
signals"
428
C7130 Display of the analog input
signals in the InNeg function
block (signal inversion)
313
−32768
(= −199.9 %)
{1} 32767
(= 199.9 %)
1 InNeg−AnV InNeg−AnIn1
2 InNeg−AnV InNeg−AnIn2
C7131 Selection of the analog input
signals for the InNeg function
block (signal inversion)
313
1 InNeg−An 1000 FIXED 0 % (not assigned) Source for InNeg−AnIn1
2 InNeg−An 1000 FIXED 0 % (not assigned) Source for InNeg−AnIn2
For possible signals see "selection list − analog
signals"
437
C7150 Display of the phase input
signals in the InNeg function
block (signal inversion)
313
−2147483647 {1} 2147483647
1 InNeg−PhiV InNeg−PhiIn1
2 InNeg−PhiV InNeg−PhiIn2