Lenze−Codestellen und CANopen−Objekte
Description of the codes relevant for the modem
8
l
63
EDSMF2181IB EN 3.0
C1208:
Country code
Code
C1208
Name
Country code
Index: 0x5B47 (23367)
Subcode Lenze Values Access Data type
253
See ^ 68
rw FIX32
¨ RSPþ PS transfer ¨ CANopen:
By means of code C1208, the code for the country in which the modem is used can be
entered.
The internal modem is approved for many countries. However, since the properties
required in the respective countries show slight differences, the modem must adapt to the
situation in each case. For this, enter the corresponding country code which is the same in
all European countries.
) Note!
Changes to this code only become effective if the mains is switched again, or
by a modem reset (code C1226).
C1223:
user name
Code
C1223
Name
User name
Index: 0x5B38 (23352)
Subcode Lenze Values Access Data type
Lenze rw VS
¨ RSPþ PS transfer ¨ CANopen:
Code C1223 can be used to enter a user name. By the Lenze setting, the user name "Lenze"
is pre−assigned to the code.
) Note!
ƒ The user name is not reset when the Lenze setting is loaded.
ƒ Observe upper and lower case letters.