EasyManua.ls Logo

Lenze EMZ9374IB - Status Messages of the Terminal Extension; Troubleshooting and Fault Elimination

Lenze EMZ9374IB
122 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting and fault elimination
Status messages of the terminal extension
8
l
68
EDBMZ9374X DE/EN/FR 4.2
8 Troubleshooting and fault elimination
8.1 Status messages of the terminal extension
Diagnostic LED
ERROR module Mode Operation Meaning
¢ll Normal operation
¢ « l Data transmission active
¢ l « Operating state pre−operational
« l ¢ Programming mode active
« l ¢
Bus OFF or communication error
The terminal extension is no longer in operation
« « « Configuration or selftest error
ERROR Meaning
¢ No error on the input/output terminals
l
Incorrect wiring
A HIGH level was applied to a terminal which
was configured as output.
l LED on ¢ LED off « LED flashing
LED of the digital inputs/outputs
I/O1 ... I/O8 Meaning
¢ Input/output is not active
l Input/output is active
l LED on ¢ LED off

Table of Contents