14 Implemented CIP™ objects
14.3 "AC Drive Profile" objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3.1 Motor Data Object (40 / 0x28)
The "Motor Data Object" provides a data basis for motor parameters.
Class attributes
Instance attributes
Instance attributes for AC motor types
For a write access to the attributes RatedCurrent and RatedVoltage, the controller enable (RFR = 0)
has to be deactivated.
Supported service codes
Attribute
ID
Service Name Data type Value
1 Get Revision UINT 1 (0x0001)
2 Get Max. Instance UINT 1 (0x0001)
3 Get Number of Instances UINT 1 (0x0001)
Attribute
ID
Service Name Data type Value
1 Get NumAttr USINT Number of supported attributes
2 Get Attributes ARRAY of
USINT
Listing of the supported attributes
3 Get / Set MotorType USINT AC motor type
6: Wound-rotor induction motor
7: Squirrel-cage induction motor
Attribute
ID
Service Name Data type Value
6 Get / Set RatedCurrent UINT Rated stator current [100mA]
7 Get / Set RatedVoltage UINT Rated base voltage [V]
Service code
[hex]
Name Description
0x01 Get_Attributes_All Outputs a list of the attributes and the attribute's values for
a certain object.
0x0E Get_Attribute_Single Outputs the value of a certain attribute.
0x10 Set_Attribute_Single Changes the value of a certain attribute.