EasyManua.ls Logo

Lenze Global Drive 8200 vector - Keypad Error Messages

Lenze Global Drive 8200 vector
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting and fault elimination
Error messages
14
L
EDK82EVXXX EN 2.0
3.2 Error messages at the keypad or in the parameter setting
program Global Drive Control
Keypad PC
1)
Error Cause Remedy
noer
0 No fault - -
ccr
71 System fault
Strong interferences on c ontrol cables Shield control cables
c
c
r
*
y
Ground or earth loops in the wiring
ce0
*
61 Communication fault to AI F
(configurable in C0126)
Faulty transmission of control commands via AIF Insert the communication module into the hand terminal
ce1
*
62 Communication fault to
CAN-IN1 with Sync control
CAN-IN1 object receives faulty da ta or
communication is interrupted
Plug-in connection - bus module Ù Check FIF
Check transmitter
Increase monitoring time under C0357/1 if necessary
ce2
*
63 Communication error to
CAN-IN2
CAN-IN2 object receives faulty da ta or
communication is interrupted
Plug-in connection - bus module Ù Check FIF
Check transmitter
Increase monitoring time under C0357/2 if necessary
ce3
*
64 Communication error to
CAN-IN1 with event or time
control
CAN-IN1 object receives faulty da ta or
communication is interrupted
Plug-in connection - bus module Ù Check FIF
Check transmitter
Increase monitoring time under C0357/3 if necessary
ce4
*
65 BUS-OFF
(many communication faults
occurred)
Controller has received too many incorrect
telegrams via the system bus and has been
disconnected
Check whether bus terminator a vailabl e
Check screen contact of the cables
Check PE connection
Check bus load, if necessary, reduce the baud rate
ce5
*
66 CAN Time-Out
(configurable in C0126)
For remote parameter setting via system bus
(C0370):
Slave does not answer. Communication monitoring
time exceeded.
Check system bus wiring
Check system bus configuration
For operation with a pplica tion I/O:
Faulty parameter setting of parameter set
changeover
In all parameter sets the signal ”parameter set
changeover” (C0410/13, C0410/14) must be combined
with the same source
For operation with module in FIF:
Internal fault
Contact Lenze
ce6
*
67 Function module system bus
(CAN) on FIF has set ”Warning”
or ”BUS-OFF”
(configurable in C0126)
CAN controller sets ”Warning” or ”BUS OFF”
Check whether bus terminator a vailabl e
Check screen contact of the cables
Check PE connection
Check bus load, if necessary, reduce the baud rate
ce7
*
68 Communication fault during
remote parameter setting via
system bus (C0370)
(configurable in C0126)
Participant does respond or is not a vailable
Check whether bus terminator a vailabl e
Check screen contact of the cables
Check PE connection
Check bus load, if necessary, reduce the baud rate
(
g
)
For operation with a pplica tion I/O:
Faulty parameter setting of parameter set
changeover
In all parameter sets the signal ”parameter set
changeover” (C0410/13, C0410/14) must be combined
with the same source
EEr
*
91 External fault (TRIP-SET) A di gi tal input assigned to the TRIP-Set function
has been activated.
Check external encoder
ErP0
...
ErP19
*
- Communication abort between
keypad and basic device
Various Contact Lenze
FAn1
*
95
E82ZMV fan module (only 8200
motec 3 ... 7,5 kW)
T
R
I
i
f
i
b
l
Fan module is defect Replace fan module
FAn1
-
TRIP or warning configurable
under C0608
Fan module is not connected Connect fan module
Check wiring
H05
*
105 Internal fault Contact Lenze
id1
*
140 Faulty parameter identification Motor not connected Connect motor
LP1
*
32 Fault in motor phase
(is displayed if C0597 = 1)
Failure of one/several motor phase(s)
Motor current too low
Check motor cables
Check V
min
boost
C
t
t
t
d
i
d
t
t
h
LP1
182 Fault in motor phase
(is displayed if C0597 = 2)
m
i
n
Connect motor to c orresponding power or adapt the
motor under C0599.