19
Commissioning
Operang Instrucons i410-Cabinet
Display code Name
Possiblesengs/
value ranges
Keypad code Informaon
P440.04 AO1 max. Signal 1000 Denion of the signal value that corresponds to the maximum value at analog output 1.
P450.01 Freq. preset 1 20.0 Hz Parameterizable frequency setpoints (preset 1).
P450.02 Freq. preset 2 40.0 Hz Parameterizable frequency setpoints (preset 2).
P450.03 Freq. preset 3 50.0 Hz * Parameterizable frequency setpoints (preset 3).
P450.04 Freq. preset 4 0.0 Hz Parameterizable frequency setpoints (preset 4).
*Defaultsengdependentonthemodel
Defaultseng=boldprint|*Defaultsengisdevice-dependent
7.4.2 Group2:Basicseng
Display code Designaon Possiblesengs Keypad code Informaon
P225.00 Quick stop decelera-
on me
1.0 s Quick stop deceleraon me for “MS: Velocity mode”
• If the “Quick stop” funcon is acvated, the motor is brought to a standsll within the deceleraon me set here.
• The set deceleraon me refers to the period of deceleraon from the set maximum frequency (P211.00) to standsll. In the case of a lower
actual frequency, the actual deceleraon me is reduced accordingly.
• Seng is not eecve in operang mode 0x6060 (P301.00) = “CiA:Velocity mode”.
7.4.3 Group 3: Motor control
Display code Designaon Possiblesengs Keypad code Informaon
P327.04 Idenfy motor data 0 ... 1 1 = start automac idencaon of the motor data.
• Inverter characteriscs, motor equivalent circuit data and controller sengs are idened and set automacally.
• The motor is energized during the procedure!
P327.05 Calibrate motor data
(non-energized)
0 ... 1 1 = start automac calibraon of the motor data.
• A default inverter characterisc is loaded.
• The motor equivalent circuit data and controller sengs are calculated on the basis of the currently set rated motor data.
• The motor is not energized.
7.4.4 Group7:Addionalfuncons
Display code Designaon Possiblesengs Keypad code Informaon
P700.01 Device commands:
Load default sengs
O / ready [0] 1 = reset all parameters in the RAM memory of the inverter to the default seng that is stored in the inverter rmware.
• All parameter changes made by the user are lost during this process!
• This process may take some seconds. When the device command has been executed successfully, the value 0 is shown.
• Loading parameters has a direct eect on cyclic communicaon: The data exchange for control is interrupted and a communicaon error is
generated.