Error code Descripon Classicaon Remedy
Blockingme
[s]
Reset possible
4281 Heatsink fan warning Warning Clean fan and venlaon slots. If required, replace fan. The fans can be unlocked via locking hooks and can
then be removed.
0 Yes
4310 Error: Motor overtemperature Error Check drive dimensions. 5 Yes
6280 Trigger/funcons connected incorrectly Trouble Check and correct the assignment of the triggers to the funcons.
When keypad or network control is acve, the two funcons “Inverter enable” (P400.01) and “Run” (P400.02)
can also be set to “Constant TRUE [1]” to start the motor.
0 Yes
7180 Motor overcurrent Error Check motor load.
Check drive dimensions.
Adapt set warning threshold or error threshold to 0x2D46:001 (P353.01).
1 Yes
9080 Keypad removed Error Plug in the keypad again or acvate another control source. 0 Yes
FF06 Motor overspeed Error Adapt the maximum motor speed (P322.00) and the warning threshold or error threshold (P350.01). 1 Yes
FF37 Automac start disabled Error Deacvate start command and reset error. 0 Yes
FF85 Keypad full control acve Warning
Press the keypad key
CTRL
to exit control mode.
0 Yes