Engineering Tools
8 | P a g e L e n z e i 5 5 0 A c t u a t o r S p e e d A O I
1 Setup
1.3 Communication Setup
1.3.1 EDS Installation in RSLogix 5000
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1.3 RSLogix 5000
Now you are ready to work in RSLogix 5000. Open it and create a new project with the controller
you are intending to use. Make sure to select the correct Type and Revision as well as assign a
Name to your controller (Figure 3).
Figure 3: New Controller
1.3.1 EDS Installation in RSLogix 5000
In order to add the i550 drive to the Ethernet/IP network in your RSLogix 5000 project, install the
EDS or Device Description file.
1) Download the latest Ethernet/IP EDS file from the Software Downloads portion of the Lenze
website (www.Lenze.com). It will be contained in a zip file Ethernet_IP_EDS_V3_0.zip. The
EDS File for the i550 Lenze drive is Lenze_IOFW51AGXX_V1-20170307.eds.
2) To install the EDS file into RSLogix 5000, use the EDS Hardware Installation Tool. Follow
Figure 4 - Figure 8 below.