EasyManua.ls Logo

Lenze i550 - Additional Functions (Group 7)

Lenze i550
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating instructions i550 cabinet frequency inverter | 42
© 11/2021 · EN · www.Lenze.com
Display code Name Possible settings Keypad code Information
P700.01 Load default settings
On / start [1]
1 = reset all parameters in the RAM memory of the inverter to the default setting stored in the inverter rmware.
All parameter changes made by the user are lost during this process!
This process may take some seconds. When the device command has been executed successfully, the value 0 is
shown.
Loading parameters has a direct eect on cyclic communication: The data exchange for control is interrupted and a
communication error is generated.
O/ready [0] Only status feedback
P700.03 Save user data
On / start [1]
1 = save current parameter settings in the user memory of the memory module with mains failure protection.
This process may take some seconds. When the device command has been executed successfully, the value 0 is
shown.
Do not switch o the supply voltage during the saving process and do not unplug the memory module from the
inverter!
When the inverter is switched on, all parameters are automatically loaded from the user memory of the memory
module to the RAM memory of the inverter.
O/ready [0] Only status feedback
Additional functions (group 7)
Commissioning
Parameter overviewTerminal controlKeypad controlImportant notesInitial switch-on
Extended
terminal control
Keypad module
Additional functions
Basic setting Motor control
Favorites

Other manuals for Lenze i550

Related product manuals