Commissioning
Parameter list
5
EN
42
Lenze ¯ MDKSEMA ¯ 5.0
5.2 Parameter list
Parameter set management
Parameter Value
Comment
Name Delivery Setting range
PIN [0000 ... 9999] PIN for the protection against unauthorised
alteration of the parameter set (0 = no
protection)
Alteration of "PIN" sets "new PIN" to the
same value
The parameters can also be read without a
PIN.
New PIN [0000 ... 9999] Future PIN for protection against
unauthorised alteration of the parameter set
Standard settings
Parameter Value
Comment
Name Delivery Setting range
Parameter set name [text] File name of the parameter set without file
extension *.lsm
Output speed 1
Order−related [−2600/i ... −500/i] rpm
[0] rpm
[500/i ... 2600/i] rpm
CCW rotation = < 0 rpm
STOP = 0 rpm
CW rotation = > 0 rpm
Lenze Smart motor with gearbox: The ratio i is
taken into consideration for the calculation of
the output speed.
Output speed 2
Output speed 3
Output speed 4
Output speed 5
Acceleration time Order−related [0.0 ... 20.0] s
nmax
ta
Acceleration time t1 of the ramp generator
from 0 rpm to n
max
[2600/i] rpm
Deceleration time Order−related [0.0 ... 20.0] s Deceleration time t2 of the ramp generator
from n
max
[2600/i] rpm to 0 rpm
Energy saving function Order−related
[Off] Optimised for:
¯ a high dynamic performance
¯ a maximum starting torque and torque
¯ a high speed accuracy
[On] Reduced energy consumption in the partial
load operational range.
Approx. 50 % of the maximum starting torque
is provided.