EasyManua.ls Logo

Lenze Smart Motor m300 MSEMA Series - Drive Behaviour in the Event of Faults; Troubleshooting and Fault Elimination

Lenze Smart Motor m300 MSEMA Series
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting and fault elimination
Drive behaviour in the event of faults
6
EN
45
Lenze ¯ MDKSEMA ¯ 5.0
6 Troubleshooting and fault elimination
6.1 Drive behaviour in the event of faults
Fault messages are stored in the Lenze Smart motor.
How to read out the fault messages:
1. Disconnect Lenze Smart motor from the mains.
2. Load parameter set to the Smartphone or the EASY Starter.
Under "History", the last 4 messages are stored.
up to firmware version 02.00.00.00:
Identical errors occurring successively are displayed as an entry.
from firmware version 02.01.00.00:
Each error is displayed as an entry.
How to reset errors:
3. Eliminate the cause of malfunction.
4. The error is reset by mains switching.
You can restart the drive.
Tip!
You can reset the fault without mains switching:
Select the input speed 0 rpm via the digital inputs.
Then select the desired speed again.
If the cause of malfunction is no longer active, the drive will restart.
Fault
Drive behaviour
Type Meaning
F Error The digital output changes to LOW = not ready for operation.
The fault is entered in the history buffer.
¯ Lenze Smart motor without brake: The motor is switched off and coasts down.
¯ Lenze Smart motor with brake: The motor is switched off; the brake is applied.
W Warning The fault is entered in the history buffer.
The Lenze Smart motor continues running.

Table of Contents

Related product manuals