Troubleshooting and fault elimination
Fault messages
6
EN
46
Lenze ¯ MDKSEMA ¯ 5.0
6.2 Fault messages
Fault
Possible cause Remedy
Type Message
F RFID read error (RFIR)
NFC communication interrupted 1. Connect and disconnect mains.
2. Repeat action.
3. If the error occurs again, please contact
the Lenze Service.
F RFID write error (RFIW)
F RFID data CRC invalid (PS02) NFC communication interrupted 1. Load default setting.
2. Connect and disconnect mains.
3. Rewrite parameter set.
F RFID data version invalid (PS04) Incompatible software version Update Lenze App or EASY Starter.
F Missing mains phase (SU02) A mains phase of a three−phase supply has
failed. Reliable detection from an
utilisation > 50 % rated motor power.
¯ Check mains connection.
¯ Check fuses.
F DC bus overvoltage (OU) DC−bus voltage too high ¯ Increase deceleration ramp.
¯ Reduce speed for great regenerative
loads.
¯ Use brake resistor.
W Electronics warning temperature (OH4) Lacking or insufficient cooling.
Drive close to being disconnected due to
overtemperature (OH1)
¯ Check cooling.
¯ Clean cooling ribs.
F Electronics overtemperature (OH1) Ambient temperature too high. Ambient temperature must be in the
permissible range.
F Electronics overload (Ixt ) (OC9) The Ixt overload test has been triggered
¯ Motor load too high.
¯ Load c
cles not com
lied with.
¯ Increase deceleration ramp.
¯ Reduce I
max
.
¯ Check dimensionin
.
F Electronics overcurrent (OC11) Overcurrent limitation active ¯ Reduce motor load.
¯ Increase deceleration ramp.
F Motor overcurrent (OC7) The maximum current monitoring
function has been triggered.
Reduce motor load.
F Motor short circuit (OC1) Short circuit in the motor phases
Reset error. If the error occurs again during
restart, please contact the Lenze Service.
F Motor earth fault (OC2) A motor phase has earth contact
F Motor overload I
2
xt (OC6) Motor thermally overloaded ¯ Reduce motor load.
¯ Check setting of the I
2
xt monitoring
function.
¯ Increase deceleration ramp.
F Brake resistor overload I
2
xt (OC12)
Too frequent and too long braking
processes
Check drive dimensioning.
Lenze Smart motor without brake resistor:
DC−bus voltage too high
¯ Reduce regenerative load.
¯ Use brake resistor.
¯ Increase deceleration ramp.
F Internal error (DH69) Various
Reset error. If the error occurs again during
restart, please contact the Lenze Service.
F Internal error (DF01)
...
Internal error (DF13)
Various