i Series e Users Guide Page 28 of 35
LIT-31903-00
4. Enter the dimmer slot/position # you need to patch
5. Press the [ENTER] button until you’re at the LUM=xxx field
6. Using the keypad, enter the Luma-Net channel you want associated with this dimmer
7. Repeat this procedure until all changes have been made
8. Press (BACK) to initiate the process of saving changes
9. You will be asked if you want to save all changes to the backplane. Enter (YES) to
permanently save the changes, or (NO) to save the changes only per this session.
NOTE: You can enter from the rack configuration menu a start address for the first dimmer position other
than 1. This has the effect of automatically renumbering every dimmer in the rack from the start address you
enter. This is a quick way to create a custom “offset” patch.
3.9 i series e HHT – Local Mode – Status_____________________
From the main local menu, there is a soft key option, [STAT], that mimics the state of the control input LED
functions and displays the current control module status condition. This display can be useful in
determining the status of the control module as it details these various control states:
• OK (normal operating condition)
• EMERGENCY (refer to section 1.64 for a functional description of emergency mode)
• BACKPLANE ERROR (unable to read serial EEPROMS on backplane, see section 1.7)
• OVERTEMP (a dimmer in the rack is in overtemp warning or shutdown)