EasyManua.ls Logo

Levitronix BPS-200 - ATEX; Iecex Certification and Marking

Levitronix BPS-200
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual for BPS-200
www.levitronix.com
PL-4012-00, Rev07, DCO# 20-144
35
9.1.5 ATEX / IECEx Certification and Marking
Specific motors together with the pump head of the BPS-200 pump system are in conformity with the
requirements of the Directive 2014/34/EU and the relevant IECEx standards. The following standards are
tested and confirmed at a certified laboratory.
IEC / EN 60079-0
Electrical apparatus for explosive gas atmospheres. General requirements.
IEC / EN 60079-15
Electrical Apparatus for explosive gas atmospheres. Construction, test and marking of type of
Anon-sparking electrical apparatus.
IEC / EN 60079-31
Explosive atmospheres 
IEC / EN 13463-1
Non-electrical equipment for use in potentially explosive atmospheres Part1: Basic method and
requirements.
IEC / EN 13463-5
Non-electrical equipment for use in potential explosive atmospheres Part5: Protection by

The Levitronix Ex motors are marked clearly and in accordance to the ATEX Directive and the relevant
IECEx standards. The protection “Ex nA means non sparking electrical apparatus.
II 3G Ex nA IIC T5 Gc
II 3D Ex tc IIIC T100°C Dc
Classification:
Category 3GD (Zone 2 for Gas and Zone 22 for Dust)
Thermal Classification:
Thermal classification of motor is T5 (< 100
0
C = 212
0
F) for maximum full-load operating
temperature at a maximum liquid temperature of 90
0
C / 194
0
F.

Table of Contents