5 Inspection and Maintenance
The LEVIFLOW
®
ultrasonic flowmeters do not require special maintenance since there are no moving parts
that can be subjected to wear and tear. However, the following periodical checks are recommended to
ensure smooth and reliable operation:
1. Check for excessive mechanical stress onto the flow sensor body for example caused by
bended piping.
2. Inspect for loosen connections caused by excessive pipe vibrations.
3. Inspect the sensor visually for any deposits, excessive bubbles or foreign materials in the
measuring tube.