MC-12HD Setup
3-45
check. To do this, the MC-12HD sends alternating calibration
noise signals to the front left and right speakers.
The MC-12HD uses the calibration noise signal to eliminate
microphones that register the signal at a level that is too low or
too high. Then, the MC-12HD determines the appropriate out-
put level for the calibration noise signal used during automatic
calibration.
CHECK MICROPHONES Results
Appears on-screen when the MC-12HD is finished checking the
microphones. This display indicates the individual check results
for each microphone.
An OK result indicates that the microphone passed the
microphone check.
An ERROR result indicates that the microphone did not pass
the microphone check.
4. Press the and arrow buttons to highlight the desired
microphone parameter. The MC-12HD refers to the micro-
phones according to the input connector to which the
microphone is connected.
5. Press the arrow button to view more detailed results for the
selected microphone. A message similar to the one shown at
the bottom of the previous column opens in the on-screen
display. Refer to the table on the next page for information
about all possible microphone check messages.
Note the following:
The MC-12HD retains the calculated microphone level until the
SPEAKER SETUP menu is closed. Once this menu is closed,
another microphone check is required before automatic cali-
bration can be performed.
For best results, you should perform automatic calibration with
four microphones that have passed the microphone check.
However, the MC-12HD will perform automatic calibration as
long as at least one microphone passes the microphone check.
In this circumstance, place the successfully checked micro-
phones in the primary listening position.
If a microphone check was successful, do not disconnect the
microphones from the microphone input connectors. If the
microphones are disconnected, you should perform the micro-
phone check again before proceeding to automatic calibration.
CHECK MICROPHONES
MIC 1
(MICROPHONE)
OK
MIC 2
MIC 3
MIC 4
PRESS TO VIEW
DETAILS
OK
OK
ERROR
OK

Table of Contents