One-dimensional bar codes
43
HIBC 39/128
Byte Field name Type Range Default value Description
0-1 Symbology ID int n/a n/a Required.
• 00 70 (hex) or 112 (dec) specifies
HIBC 39 PAS symbology
• 00 71 (hex) or 113 (dec) specifies
HIBC 39 SLS symbology
• 00 72 (hex) or 114 (dec) specifies
HIBC 128 PAS symbology
• 00 73 (hex) or 115 (dec)Specifies
HIBC 128 SLS symbology
2 HRT Location int 0=Default
(Under)
1=No HRT
2=Embedded
3=Half-
Embedded
4=Under
5=Above
• 0 or 4 (dec)
or
• 00 or 04
(hex)
Optional.
Corresponds to the HP #p
parameter.
3 HRT Typeface int 0=Courier
1=SM Gothic
2=SM Unit
3=SM Unit
Condensed
4=Roman
5=OCRB
•0 (dec)
or
•00 (hex)
Optional.
Corresponds to the HP #h
parameter.
4 HRT Style int 0=Regular
1=Italic
2=Bold
(default)
3=Bold Italic
•2 (dec)
or
•02 (hex)
Optional.
Specifies the font style used for
HRT.
Note: Default font style for OCRB is
Regular only.
5 Bar Height Units int 0=Default
(1/600” units)
1=1/300”
units
2=1/600”
units
3=1/1200”
units
• 0 or 2 (dec)
or
• 00 or 02
(hex)
Optional.
Specifies units for bar height
dimensions.