Diagnostic aids 3-29
7525-xxx
Go Back
Previous
Next
Sensor2 test
This test verifies the functionality of scan sensor 2. To test this sensor. perform the following steps:
1. In the sensor test menu, press or to scroll to the Sensor 2 test.
2. press Select (). Starting Test displays. Sensor 2: Closed displays.
3. Lift the ADF top cover, and close the ADF cover sensor (A) by pressing down on the ADF sensor actuator
with a small flat blade screwdriver.
4. Move the Sensor 2 actuator by inserting a small screwdriver into the hole (B) and gently toggling the
actuator. Sensor 2: Open should display if the sensor is working properly.
5. press Back ( ) to exit the test and return to the Scanner sensor tests.
A
B