Repair information 4-43
7525-xxx
Go Back
Previous
Next
3. Rotate the release lever (C) in a counter clockwise direction with a spring hook or needlenose pliers to
decouple the ITU while pulling the ITU toward the front.
4. Hold the release lever while removing the ITU.