Delta Elec. Inc. BS254_BX254_BX324 rev.06
Company Confidential LG ______________________ Delta____________
19
2011/06/16
Confirmation with none-signal state
• CW Sensor Board
Ass’y malfunction
• Main Board
Ass’y malfunction
• DMD Set malfunction
• Lamp deterioration (malfunction/usage time)
• Power Supply Unit malfunction
(No change occurs even after lamp replacement.)
• DMD Set malfunction
(No change occurs even after lamp replacement.)
Press “Menu” key
• Remote controller set malfunction, Low battery, and outside
operation rang
• Main Board Ass’y malfunction
• Connector (P704)、(P8103 of IR PWB) disconnected
• IR PWB Ass’y malfunction
• Check the pattern generator setting is wrong
• Main Board Ass’y malfunction
• DMD Set malfunction
• Setting on PC side(external output setting, resolution, etc.)
• Cable malfunction (disconnection and pins broken)
normally
Input each signal
• Connector (P902) disconnected
• Speaker Ass’y malfunction
• Main Board Ass’y malfunction
“No signal” Message display