Chapter 8. MK PROGRAMMING
8 - 6
(OUT M0200)
[ END ]
[
RPUT hC000 h000B D0100 00000 00001
D0000 ]
[ <= D0100 4000 ]
[ DBINP P001 D0100 ]
6.2.3 Programming for Mounting D/A Conversion Module on Remote I/O Station
This is programming for output D/A conversion value set by digital switch.
1) System Configuration
2) Initial Settings
(1) Enabled channel : channel 0,
3) Descriptions of the Program
(1) P0020 turning On leads to displaying D/A conversion value set by digital switch on channel 0.
4) Program
(P0010 ~ P001F)
(P0020)
Storing the BCD digital value to D100
Writing the values stored in D100 to buffer memory of address 0
If the BCD digital switch value is equal to or less than 4000 M200 is turned ON
digital switch
Remote
Station
No.11(0Bh)
GM4-
PA1A
K4P -
15AS
G4L-
FUEA
G4I-
D22A
G4I-
D22A
GM4-
PA1A
G4L-
RBEA
G4F-
DA2V
P0020
M0200