Sensor Position Map
Description Purpose & Position
F-Sensor F Room temp measure
R2-Sensor R Room temp measure
D-Sensor Defrost start/exit temp measure
R1-Sensor R Room temp measure
RT-Sensor Environment temp measure
Disp.
(F)
(除霜)
(R1)
(R2)
(RT)
NO Error mode
Load Control
COMP F-FAN C-FAN Def-Heater Damper
1 Normal
2 FS E
15m ON/
15m OFF
Standard
RPM
3 rS E
Standard
RPM
10m OPEN/
15m CLOSE
4 r2 E
5 dS E
Standard
RPM
No Defrost
(exit immediately)
6 rt E
(No RT
compensate)
7 dH E
Standard
RPM
8 FF E
OFF
(Recheck
after 30m)
9 CF E
OFF
(Recheck
after 30m)
10 CO E
Standard
RPM
Note: means control normally
- 34-