Parts Defect Determination in Power On Status
Parts Defect Determination in Power On Status
Check of Power Application
-Check that supply power of +15V, +8V used as supply power of digital circuits is normally applied.
COMPRESSOR
+15V +8v
Measuring part
D202 Pin2-GND D203 Pin2-GND
Normal 13V-15.5V 7V-9V
Defect 13V or less 7V or less
Measures Replace board Replace board