u Temperature compensation table at the cold storage room is as follows:
u This circuit is a circuit to enter the necessary level of temperature compensation for adjusting different temperature every
model at the cold storage room into MICOM.
EXPLATION FOR MICOM CIRCUIT
- 54 -
470 Ω 2 kΩ 3.3 kΩ 5.6 kΩ 8.2 kΩ 10 kΩ 12 kΩ 18 kΩ 33 kΩ 56 kΩ 180 kΩ
No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C3 °C 3.5 °C4 °C 4.5 °C5 °C
470Ω
change
Up Up Up Up Up Up Up Up Up Up
0.5 °C No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C3 °C 3.5 °C4 °C 4.5 °C
2 kΩ
Down change
Up Up Up Up Up Up Up Up Up
1 °C 0.5 °C No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C3 °C 3.5 °C4 °C
3.3 kΩ
Down
Down
change
Up Up Up Up Up Up Up Up
1.5 °C1 °C 0.5 °C No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C3 °C 3.5 °C
5.6 kΩ
Down Down Down
change
Up Up Up Up Up Up Up
2 °C 1.5 °C1 °C 0.5 ° No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C3 °C
Cold storage
8.2 kΩ
Down Down Down
Drop
change
Up Up Up Up Up Up
room
2.5 °C2 °C 1.5 °C1 °C 0.5 °C No 0.5 °C1 °C 1.5 °C2 °C 2.5 °C
(RCR1) 10 kΩ
Down Down Down Down Down
change
Up Up Up Up Up
3 °C 2.5 °C2 °C 1.5 °C1 °C 0.5 °C No 0.5 °C1 °C 1.5 °C2 °C
12 kΩ
Down Down Down Down Down Down
change
Up Up Up Up
3.5 °C3 °C 2.5 °C2 °C 1.5 °C1 °C 0.5 °C No 0.5 °C1 °C 1.5 °C
18 kΩ
Down Down Down Down Down Down Down
change
Up Up Up
4 °C 3.5 °C3 °C 2.5 °C2 °C 1.5 °C1 °C 0.5 °C No 0.5 °C1 °C
33 kΩ
Down Down Down Down Down Down Down Down
change
Up Up
4.5 °C4 °C 3.5 °C3 °C 2.5 °C2 °C 1.5 °C1 °C 0.5 °C No 0.5 °C
56 kΩ
Down Down Down Down Down Down Down Down Down
change
Up
5 °C 4.5 °C4 °C 3.5 °C3 °C 2.5 °C2 °C 1.5 °C1 °C 0.5 °CNo
180 kΩ
Down Down Down Down Down Down Down Down Down Down
change
Modification
resistance
Current
resistance