EasyManua.ls Logo

LG GC-P207

LG GC-P207
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Description of Function
2-1. Funnction of Temperature Selection
* The temperature can vary ±3 °C depending on the load condition. *( ) : 127V/60Hz, 110~115V/60Hz, 115V/60Hz Rating ONLY.
*< > : TAIBEI
1. When power is initially applied or reapplied after power cut, Medium is automatically selected.
2. When the temperature selection switch in the freezer and refrigerator compartments is pressed, the light is on in the
following sequence:
"Middle" "Middle Strong" "Strong" "Weak" "Middle Weak"
3. The temperature setting condition of freezer and refrigerator compartments shall not be indicate in the standard model
(GC-P207, GC-L207, GC-C207, GC-B207, ) when refrigerator or home bar door is closed.
MICOM FUNCTION
- 23 -
Division Power Initially On 1st Press 2nd Press 3th Press 4th Press
Type-1
(88-LED)
Type-2
(Bar-LED)
Type-3
(Dot-LED)
-
19 °C 3 °C
-
22°C 2 °C
-
23 °C 0 °C
-
15 °C 6 °C
-
17 °C 4 °C
Change
of
Indication
Lamp
Temperature
Control
Middle Middle Strong Strong Weak Middle Weak
-19 °C
(-18 °C)
<-19 °C>
3 °C
<2 °C>
1.5 °C
<1 °C>
0 °C
<0 °C>
6 °C
<4.5 °C>
4.5 °C
<3 °C>
-21 °C
(-21 °C)
<-21 °C>
-23 °C
(-22 °C)
<-22 °C>
-15 °C
<-16.5 °C>
-17 °C
<-18 °C>
Freezer
Control
Refrigeration
Control

Table of Contents

Related product manuals