14 | PRODUCT DATA
Single Zone Mega Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
FUNCTIONS, CONTROLS, OPTIONS
Table 6: Indoor Units—Functions, Controls and Options.
Indoor Unit Type LS090-120-180-240HEV1 LS090-120HXV
Airow
Air supply outlet
1 1
Airflow direction (left/right)
Manual Auto
Airflow direction (up/down)
Auto Auto
Auto swing (left/right)
X √
Auto swing (up/down)
√ √
Airflow steps (fan/cool/heat)
4 / 4 / 4 6 / 6 / 6
Auto swing
√ √
Auto wind
√ √
Jet-cool/heat
√ / √ √ / √
Swirl wind
X X
One touch soft air
√ X
Air Purifying
Washable anti-fungal
1
√ √
Deodorizing filter
X X
Plasma
2
X X
Allergy free filter
X X
3M Micro Protection filter
2
X X
Functions
Drain pump
X X
E.S.P. control
X X
Electric heater
X X
High ceiling
X X
Defrost
√ √
Low ambient
√ √
Hot start
√ √
Self diagnostics
√ √
Soft dry (dehumidification)
√ √
Auto changeover
√ √
Auto clean (coil dry)
√ √
Auto restart
√ √
Child lock
X X
Forced operation
√ √
Sleep mode
√ √
Timer (24hr on/off)
√ √
Weekly timer
X X
Two thermistor control
X X
Controllers
Wireless Remote Controller
√ √
Simple Controller with Mode Selection
X o
Simple Controller without Mode Selection
X o
LG Programmable Thermostat
X o
Dry contact
X o
Central control (LGAP)
X X
PI 485
X X
Special Function Kit
Zone control
X X
CTIE
X X
Electro thermostat
X X
Wi-Fi Module (Option)
X X
Water level sensor connection (for optional AG-9300-LG)
o o
Wind baffle kit
X X
Other
Thermistor
X X
1
Primary washable filters.
2
Secondary filters.
√ = Standard feature
o = Optional accessory (must be purchased separately)
X = Not available