- 96 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
5. Trouble Shooting
6.13 Check code Trouble shooting CH23, CH28
Check the wire
connection.(U,V,W)
Is it normal ?
Is it normal ?
Yes
Yes
No
Correct
connection
No
Change
Compressor
Check the input power
Is it normal ?
Yes
No
Change
Compressor
Check Flow Chart
❊ Dc link voltage table
❊ Check TRANS1
❊ Check DC link voltage
Type Non operating Operating
1 Phase AUUW126C PSC DC300V ± 10% DC280V ± 10%
AUUW186C PSC DC300V ± 10% DC280V ± 10%
AUUW246D PFC DC300V ± 10% DC380V ± 10%
AUUW306D PFC DC300V ± 10% DC380V ± 10%
AUUW366D PFC DC300V ± 10% DC380V ± 10%
AUUW426D PFC DC300V ± 10% DC380V ± 10%
AUUW486D PFC DC300V ± 10% DC380V ± 10%
AUUW606D PFC DC300V ± 10% DC380V ± 10%
3 Phase AUUW368D PSC DC540V ± 10% DC500V ± 10%
AUUW428D PFC DC540V ± 10% DC680V ± 10%
AUUW488D PFC DC540V ± 10% DC680V ± 10%
AUUW608D PFC DC540V ± 10% DC680V ± 10%
Model
DC Link Voltage
V
CN_TRANS 1
23
28
DC Link
Low voltage.
DC Link
High voltage
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• Check the power source.
• Check the components.
• Check the power source.
• Check the components.
Display
code
Title Cause of error Check point & Normal condition
→
→
→
→