168
INSTALLER SETTING
ENGLISH
Energy state
This function is to control the product according to the energy state. When the charged state of
ESS is transmitted, it changes the target temperature of heating, cooling and DHW by setting
value according to energy state.
Select either Signal Mode or Modbus Mode according to the connection type between the
product and the ESS.
OK
OK
When Signal Mode of EES use type is selected, press the Digital Input Assignment button to set
the energy state according to the input signal.
Value
Input Signal Output state
ES1 ES2 Default Range
X 0 0 ES2 fixed
X 1 0 ES1 fixed
0:1 0 1 ES3
ES3-ES8
1:1 1 1 ES4