The SMPS30 is only compatible with LA43 IC and the LA44 IC.
The SMPS30 is not suitable for outdoor applications
Before installation, re-installation or troubleshooting
Stop the application
Switch off the power supply and pull out the mains plug
Relieve the application of any loads, which may be released during the work
Before start-up
Make sure that the system has been installed as instructed in the User Manual
System connection. The individual parts must be connected before the SMPS30 is connected to the mains.
During operation
Ensure that the cables are not damaged
Unplug the SMPS30 before moving the equipment
Device protection:
The SMPS30 contains several mechanisms to protect itself from being damaged due to excessive use.
In case of overheating, the device will activate a thermal protection. No power output will be available until the temperature is back again within
normal operating range.
In case of exceeding the current limit / failure in the actuator, the device will activate an overload protection. Immediately after the situation has
been remediated the power output will be available again.
Hot plugging
It is not allowed to remove or to add the output cable as long as the SMPS is powered by mains.
Maintenance/cleaning
The SMPS30 must be cleaned at regular intervals to remove dust and dirt and it must be inspected for mechanical damage, wear and breaks
It is not allowed to spray directly with a high-pressure cleaner on the device
Interconnecting cables must remain plugged in, correctly fitted with O-rings, during cleaning to prevent ingress of water
The SMPS30 is resistant to the majority of cleaners and disinfectants used in the hospital and nursing home sector.
However, the detergents must comply with the following basic requirements
- They must not be highly alkaline or acidic (pH value 6-8)
- They must not contain caustic agents
The Under Bed Light (UBL) can be mounted under the bed to provide a discrete guiding
light when the patient leaves the bed during night. With an Under Bed Light it is easy to
switch the light on and off by means of a handset or controlling it automatically with the
Out of Bed functionality of the MJB8.
14. Under Bed Light (MEDLINE
®
CARELINE
®
)
Usage:
Operating temperature: + 5 °C to + 40 °C
Storage temperature: - 10 °C to + 50 °C
Atmospheric pressure: 700 to 1060hPa
Approvals: IEC 60601-1, ANSI/AAMI ES60601-1,
CAN/CSA-22.2 No 60601-1
Connectivity: To be connected to MJB5 and MJB8
Recommendations
The Under Bed Light (Item P/N.: 0964135) must be mounted on the bed with metal screws in order to maintain ESD protection.