3.6 Environment conditions
• Stationary Lubrigun Pumps / Pump units are
designed for use in closed areas protecting the
equipment against weather; in the case of mobile
equipment being used outdoors, the equipment must
be stored safely protected.
Contamination of the material to be pumped must be
avoided during operation as well as storage.
• Ambient temperature
⇒ Refer to ‘Technical Data’ of the pump.
If the equipment is operated at ambient tempe-
ratures lower than room temperature, it must be
ensured that pumpability of the material is not
restricted. That also concerns the storage of
material.
The user must take care for pumpability of the
material.
3.
7 Space required
• The space being required individually depends on
the pump assembly and the dimensions of the
material container/drum.
Note: On estimating the space requirement or on
installation of the pump/pump unit also take into
consideration:
− Transport of material containers
Allow unrestricted supply, putting-up and removal of
material containers.
− Controls
Allow access to controls of the pump (for example
shut-off valves, quick-couplings, regulators, shut-off
devices, etc.) without hindrance.
− Connecting points of the pump
Allow access to connecting hoses for compressed
air and material.
Connecting hoses to be freely movable without
obstacles.
− Removal of the pump
Allow sufficient clearance for lifting the pump off of the
container (for lifting manually or by pulley or by
pneumatic lift).
3.
8 Location
Locate pump / pump unit as close as possible to the
outlet for the material consumer. Select a place that
allows a favourable pipe run (short and straight) of the
material supply line.
Pump and drum/container must be rigidly installed
upright.
The location of the pump/pump unit must have:
• Facility for compressed air supply
− Air supply line for connecting pump drive
⇒ Refer to ‘Technical Data’ of the pump; also see
previous page, sections ‘Air supply’ and
‘Pneumatic system components’.
• The equipment must be easily accessible.
Plan sufficient room for operating and servicing
pump/pump unit and handling of material containers.
• Locate equipment at a light place.
Name plates, instructions and warnings to be legible.
Operating and service personnel must be able to
examine pump/pump unit in order to keep equipment
in good working conditions and to make out any
malfunction or defects in time.
• Location to have plane and firm ground
If equipment mounted on mobile platform, the pump,
drum cover and container must be securely
fastened.
• Location to have flat horizontal surface.
Note
Pay attention to owner´s directives and regulations of
authority!
When using materials which are hazardous to
environment adhere to prevailing national regulations
for safe location and attachments.
Operation Guidance. Air operated Lubrigun Pumps 50 : 1