4. Erection & Installation
4.1 Safety Instructions
Warning
Do not operate pneumatic pump drive
with combustible gas.
Do not exceed the stated working
pressure of the pump.
Visually check pump for proper condition on
unpacking. Claim immediately in case of any
damage.
Installation and initial operation of the equipment
shall be carried out by skilled, qualified personnel
only.
4.
2 Tools required
No special tools required to install the pump.
4.
3 Erection of Pump
Locate pump at convenient place.
Refer to section ‘Guidance for operation’ for general
information.
The outlet body of the pump has four threaded holes for
fastening to drum cover. The pump can be also
fastened to cover using a mounting kit.
See section ‘Dimensions’ of the pump.
Fasteners not included, to be added at site by user.
Securely fasten pump to avoid vibration. Rigidly install
pump on a firm and plane horizontal base.
4.
4 Installation
Note: Pumps are factory tested with light oil and some
of it is left in the pump tube to protect pump parts during
storage and transportation.
If required, before using flush pump to prevent
contamination of material to be pumped.
Warning
Do not use flammable liquids for
flushing/cleaning.
CAUTION
Do not use fluids not compatible with
the wetted parts of the pump tube.
Do not use fluids not compatible with the wetted parts of
the pump tube.
See 3.
3 ‘Technical Data’.
Note
Section 3.
5 ‘Operation guidance’ contains general
information about components required for air operated
Lubrigun Pumps 50:1, notes concerning material and air
lines as well as notes concerning the location for
erecting.
Remark: A material pumping system can consist of a
variety of individual system components and for that
reason, information and instructions for erection and
installation:
See Operating Instructions of the manufacturer/
supplier of the complete material dispensing system.
General information for installation
Pump / Pump unit
Putting up
See section ‘Operation guidance‘, informing
about place, room and location.
Locate pump at convenient place.
Install pump and container on a firm and plane
horizontal base.
Securely fasten pump and container preventing to
tilt; anchor equipment to base if necessary.
While opening material container or container is open:
Avoid contamination of the material to be pumped.
Pump with drum cover & follower plate.
Place drum at place selected.
Remove head from the drum.
Put follower centrally into drum; guide of center hole
to show upwards. Push follower plate manually onto
material in order to expel all air underneath the follower.
Fasten pump on drum cover.
Lift pump and manually guide pump tube through
center hole of follower plate down until drum cover
contacts rim of the drum.
After drum cover is located on top of the drum:
Adjust (center) drum cover on the drum if required
and then fasten drum cover to drum by screws.
Supply lines
On installation, note:
Points for connecting pump to supply line should be
close to the pump assembly.
Shut-off valves, controls, etc. must be easily ac-
cessible.
Connecting hoses should be movable without ob-
stacles.
Properly assemble air line and pneumatic com-
ponents being required to control and monitor the
pump. Not yet couple air hose to pump drive.
Air lines must be free from dirt and scale.
Blow foreign particles off before installing lines.
Properly assemble material line and system
components, for example safety device, shut-off
valves, etc.. High pressure quarter-turn valve is
normally used in connecting line of pump.
Screw high pressure connecting hose to material
outlet of pump.
Securely fasten lines and components. High pressure!
Ground pump/equipment according to electr. rules
and practice.