EasyManua.ls Logo

Linde E15 - Check Fan on Drive Axle and Cross Fan for Soiling, Clean as Necessary

Linde E15
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servicing 5
Inspection and maintenance every 500 to 1000 operating hours or once a year
Check fan on drive axle and cross
fan for soiling, clean as necessary
ENVIRONMENT NOTE
Take note of information about working mate-
rials.
Clean drive axle fan
¾ Park truck safely
¾ Fully lower load fork
¾ Switch off key switch
¾ Remove rubber mat from floor plate
¾ Unscrew four fastening screws o
f floor plate
¾ Detach plug from drive control pedal system
and put floor plate to one side
¾ Remove fan shroud
¾ Clean fan with compressed air and/
or cold
cleaner
Clean cross fan
e3861303
1
2
3
¾ Remove cover (2) together with fan by un-
screwing four fastening screws (1)
¾ Clean fan (3) with compressed air and/or
cold cleaner
Operating Instructions 386 807 1001 EN 03/2006 111