Akurate Kontrol pre-amplifier - RS232 ASCII Interface Specification and Commands - Version 1.2
11
1.8: Status Command
The status command has been provided as a debugging aid, i.e. the host can find out why a command was
not processed.
1.8.1: STATUS
$STATUS$
!$STATUS sc (sv)$
Return the status of the last command
Where scis the returned status code and svis the status value (only used with code 25 for now). Codes
are allocated on a block basis for each product with the first 48 codes reserved for general use.
1.8.1.1: Status Codes
The following table lists the General Status Codes which all products support.
Code
Description
00 (0x00)
- No error
01 (0x01)
- Unexpected termination of command line
02 (0x02)
- Unrecognised or misplaced character in command line
03 (0x03)
- Corrupted command message (within $….$)
04 (0x04)
- Start of another source identifier, identifier has already been supplied
05 (0x05)
- Start of another group identifier, identifier has already been supplied
06 (0x06)
- Start of another destination identifier, identifier has already been supplied
07 (0x07)
- Source identifier is too large, maximum of 20 characters
08 (0x08)
- Group identifier is too large, maximum of 20 characters
09 (0x09)
- Destination identifier is too large, maximum of 20 characters
o
10 (0x0A)
- Source identifier corrupted
11 (0x0B)
- Group identifier corrupted
12 (0x0C)
- Destination identifier corrupted
o
13 (0x0D)
- Unknown group identity
14 (0x0E)
- Unknown destination identity
o
15 (0x0F)
- Unknown command
16 (0x10)
- Unknown command parameter
o
17 (0x11)
- Parameter missing from ID command
18 (0x12)
- Unknown product identifier, cannot delete
o
19 (0x13)
- Parameter missing from GID command
20 (0x14)
- Cannot delete group identifier, unknown
21 (0x15)
- Cannot add new group identifier, already exists
22 (0x16)
- Cannot add new group identifier, list full
o
23 (0x17)
- Polling must be activated by the POLL START command
24 (0x18)
- Only POLL ID, SLEEP or DONE commands accepted during polling
o
25 (0x19)
- Message exceeded maximum allowable length
- sv‟ defines maximum length (upto and including CR, and excluding LF)
o
26 (0x1A)
up to
47 (0x3F)
- Reserved

Other manuals for Linn Akurate Kontrol

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linn Akurate Kontrol and is the answer not in the manual?

Linn Akurate Kontrol Specifications

General IconGeneral
BrandLinn
ModelAkurate Kontrol
CategoryAmplifier
LanguageEnglish

Related product manuals