Akurate Kontrol pre-amplifier - RS232 ASCII Interface Specification and Commands - Version 1.2
Return current setting.
Increase or decrease current setting by one.
Increase or decrease current setting by supplied value.
Set to absolute value supplied.
!$VOLUME LIMITS min_value max_value$
Return minimum and maximum settings (0 to 100 inclusive).
Note: The Akurate Kontrol volume can be specified in half steps, for example, a volume of 75.5 is now
permissible.
3.1.5: BALANCE
3.1.5.1: BALANCE / BALANCE_LR (left/right)
$[BALANCE|BALANCE_LR] ?$
!$[BALANCE|BALANCE_LR] value$
Return current setting (-ve is left biased, +ve is right biased).
$[BALANCE|BALANCE_LR] [+|-]$
!$[BALANCE|BALANCE_LR] value$
Increase or decrease current setting by one.
$[BALANCE|BALANCE_LR] [+|-]value$
!$[BALANCE|BALANCE_LR] value$
Increase or decrease current setting by supplied value.
$[BALANCE|BALANCE_LR] = [+|-]value$
!$[BALANCE|BALANCE_LR] value$
Set to absolute value supplied.
$[BALANCE|BALANCE_LR] LIMITS$
!$[BALANCE|BALANCE_LR] LIMITS min_value max_value$
Return minimum and maximum settings (-9 to +9 inclusive).