Akurate Kontrol pre-amplifier - RS232 ASCII Interface Specification and Commands - Version 1.2
14
2: System Commands
The following pages contain the command set for the analogue Akurate Kontrol pre-amplifiers.
Important:
1
Parameters must be separated from commands and each other by at least one space character
2
Where a command can be enabled or disabled then
Y or ON will enable (turn on) the setting and N or OFF will disable (turn off) the setting
2.1: Command Help
Command help is implemented by the Akurate Kontrol and will give the host details for any given command.
for example: $? SEARCH$
replies with: !$? SEARCH (?|+|-|int|+int|-int|<|>|STOP)
2.2: System Commands
The system commands supported by the Akurate Kontrol are ID, GID, BAUD, RESET, ECHO, POLL,
STATUS,INIT, IR,VERSION,COUNTER and Power_Up Message. These are all explained in section 0
System Commands of this document.