RCU/IR SOCKET
Define the use of the socket marked RCU on the back panel.
Options:
RCU*
(KNEKT Room Control Unit),
IR
(Infrared Repeater)
Default setting:
RCU
* For use with Linn KNEKT systems only.
PRODUCT IR
Enable or disable the infrared receiver on the front of the unit.
Options:
ENABLED, DISABLED
Default setting:
ENABLED
RS232 SETUP
Accesses the RS232 SETUP sub-menu.
The RS232 Setup sub-menu is for use if the AKURATE KONTROL is
communicating with other RS232 enabled products (e.g. a third-party
controller).
BAUD RATE
Set the baud rate to suit the RS232 protocol being used.
Range:
4800 to 2
30400
(9 settings)
Default setting:
9600
PARITY
Set parity to suit the RS232 protocol being used.
Options:
EVEN, ODD, NONE
Default setting:
EVEN
DATA BITS
Set the data bits to suit the RS232 protocol being used.
Options:
7, 8
Default setting:
7
SELECTION TIMEOUT
Set the time the AKURATE KONTROL takes to select a source when
the source is changed.
Range:
1 SEC.. to 10 SEC.
Default setting:
2 SEC.
STARTUP SOURCE
Set the source the AKURATE KONTROL selects when brought out of
standby.
Options:
LAST USED, NONE, (any of the source inputs)
Default setting:
LAST USED
STANDBYY RECORD FROM
You can record from a source component to a recording device
through the AKURATE KONTROL, even if the AKURATE KONTROL is
in standby mode.* Set which source you want the AKURATE
KONTROL to select when it is in standby.
Options:
LAST USE
D, NONE, (any of the sources), KNEKT**
Default setting:
LAST USED
* For information on setting-up a record path see Record function,
page 23.
** Is only available when KNEKT (see below) is set to LOCAL ROOM.
KNEKT
If your AKURATE KONTROL is installed in a Linn KNEKT multi-room
system, select the appropriate setting. If your AKURATE KONTROL is
not installed in a KNEKT system, select
NONE
.
Options:
NONE, MAIN ROOM, LOCAL ROOM, INTERSEKT
Default setting:
NONE
12 AKURATE KONTROL
ENGLISH

Other manuals for Linn Akurate Kontrol

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linn Akurate Kontrol and is the answer not in the manual?

Linn Akurate Kontrol Specifications

General IconGeneral
BrandLinn
ModelAkurate Kontrol
CategoryAmplifier
LanguageEnglish

Related product manuals