43
4.3.1.2 Output Terminals
Table 4.3.1.2 Control Circuit Output Terminals
Multi-Function
Relay Output
Relay output
DC 30 V, 3 A
AC 250 V, 5 A
Multi-Function
Photocoupler
Output
Photocoupler Output terminal 1 (zero speed)
Photocoupler Output
48 V, 2 to 50 mA
Photocoupler Output terminal 2 (speed agree)
Photocoupler Output terminal
Multi-Function
Analog Output
Programmable analog output terminal (output
frequency)
Voltage Output
0 to 10V, -10 to +10V
Multi-function analog output terminal (output
current )
Voltage or current output
(Selectable) 0 or 4 to
20mA, 0 to 10V
Multi-Function
Pulse Train
Output
Multi-function pulse train output (output
frequency)
Pulse train common terminal
<1> Do not assign frequent switching functions such as ON/OFF to terminals R1 and R2, which may
shorten the relay terminal life.