42
4.3.1.1 Input Terminals
Table 4.3.1.1 Control Circuit Input Terminal
Multi-Function
Digital Inputs
Digital input terminal 1 (forward/stop)
Optocoupler 24 V, 8 mA
It is set to the Sink mode at the
factory.
Please use the Sink/Source switch
to select the multi-function digital
input contact mode.
Digital input terminal 2 (forward/stop)
Digital input terminal 3 (external fault 1)
Digital input terminal 4 (fault reset)
Digital input terminal 5 (multi-step speed 1)
Digital input terminal 6 (multi-step speed 2)
Digital input terminal 7 (Jog command)
Digital input terminal 8 (Baseblock (normal
open))
Digital input common contact, the inverter provides Sink/Source mode switching,
please pay attention to this mode setting when connecting.
Multi-Function
Analog Inputs
Auxiliary power terminal +10V
Auxiliary power terminal -10V
Analog input terminal 1
(main frequency command)
Voltage input
0 to 10V / -10V to +10V
Analog input terminal 2
(auxiliary frequency command)
Voltage or current input
(Selectable). 0 or 4 to 20mA, 0 to
10V, 0 to 5V
The ground terminal for control
signals to avoid interference. Use
shielded cables only.
Common terminal for analog signals
Motor temperature signal terminal
Connects the temperature sensor
of AC motor for the drive to know
the motor temperature and trigger
necessary protections.
Digital control signal power +24V
Provide digital control signal power
+24V/50mA
Pulse train input
(frequency command)
Input frequency up to 32KHz
Common terminal for pulse train signals