52
terminal input E1-□□= 3 (LOCAL/REMOTE Selection), E1-□□= 4 (Command Source 1/2
Selection) . Refer to parameter group E1 and LO/RE Key Function Selection (o2-00).
Enables or disables the protection to avoid an active Run command at the new source causing
a sudden movement on the motor when the command source is switched from the old source
to the new source.
No.
Name
Setting Range
Default
b1-05
Run Command Action after Switch
0, 1
0
0 : Ignore Active Run Command at the New Source
If a Run command at the new source is active, the drive will not start or the drive will stop
operation if it was running, when switching from the old source to the new source. The drive
can start only when the Run command is removed and given again.
1 : Accept Active Run Command at the New Source
WARNING! If a run command at the new source is active, the drive will accept it and run the motor immediately
right after switching from the old source to the new source. Clear all personnel from the electrical connections and
the running machinery prior to switching command sources. Failure to comply could cause serious injury.
b1-06 Run Command Selection during Programming
For safety reasons, the drive will ignore a Run command when the keypad is being used to edit
parameters in Programming Mode. If allowing a Run command during programming is
required in the application, set this parameter to 1.
No.
Name
Setting Range
Default
b1-06
Run Command Selection during Programming
0 to 2
0
0 : Run command disabled during Programming
A Run command is not accepted when the keypad is being used to edit parameters in
Programming Mode.
1 : Run command enabled during Programming
A Run command is accepted when the keypad is being used to edit parameters in
Programming Mode.
2 : Prohibit programming during run
The programming mode cannot be displayed during run except for monitoring parameter
Group U.
b1- 10 Run Command at Power up

Table of Contents

Other manuals for LiteOn EVO600043S2D2E20F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LiteOn EVO600043S2D2E20F and is the answer not in the manual?

LiteOn EVO600043S2D2E20F Specifications

General IconGeneral
BrandLiteOn
ModelEVO600043S2D2E20F
CategoryController
LanguageEnglish

Related product manuals