Lite-On Technology Corp.
Industrial Automation
119
The filter bandwidth for the speed detection
Communication
address:
0126H
0127H
This is used to set the filter bandwidth for speed estimation.
The gain of the position control
Communication
address:
0128H
0129H
When the gain of the position control is increased, the position response is increased and the error magnitude of
the position control is reduced. Vibration and noise occurs easily if the gain is set to an excessive value.
Ratio for the gain variation of the position
control
Communication
address:
012AH
012BH
This is used to switch the change rate regarding the gain of the position control based on the condition of gain
switch.