EasyManua.ls Logo

LiteOn ISA-7 Series - User-Specified DI and DO Signals

LiteOn ISA-7 Series
237 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lite-On Technology Corp.
Industrial Automation
51
3.3.4. User-specified DI and DO signals
If the desired DI/DO signal can't be found among the default ones, the user may set new DI/DO. The
function of the DI1~9 and DO1~6 signals depend on the parameters PC-01~PC-09 and PC-10~PC-15.
Refer to the following table. Input the DI or DO code in the corresponding parameter to set the
function of this DI/DO.
Signal Name
Pin No
Corresponding
parameter
Signal Name
Pin No
Corresponding
parameter
Standard
DI
DI1-
CN1-9
PC-01
Standard
DO
DO1+
CN1-7
PC-10
DI2-
CN1-10
PC-02
DO1-
CN1-6
DI3-
CN1-34
PC-03
DO2+
CN1-5
PC-11
DI4-
CN1-8
PC-04
DO2-
CN1-4
DI5-
CN1-33
PC-05
DO3+
CN1-3
PC-12
DI6-
CN1-32
PC-06
DO3-
CN1-2
DI7-
CN1-31
PC-07
DO4+
CN1-1
PC-13
DI8-
CN1-30
PC-08
DO4-
CN1-26
DI9
CN1-12
PC-09
DO5+
CN1-28
PC-14
DO5-
CN1-27
DO6+
CN1-16
PC-15
DO6-
CN1-15

Table of Contents

Related product manuals