7.5.3. Analog monitoring
The drive provides two analog channels. The user observes the drive status needed through analog
monitoring.
PD-22
VMON
Analog output monitoring
Communication
address:
032CH
032DH
Initial value
01
Control mode
ALL
Unit
N/A
Configuration range
00 ~ 0x55
Data size
16bit
Data format
Hex
PD-28
VMR1
Ratio for MON1 analog monitoring
output
Communication
address:
0338H
0339H
Initial value
100
Control mode
ALL
Unit
%
Configuration range
0 ~ 100
Data size
16bit
Data format
Dec
Disabling of maximum
speed limit
Activation of
maximum speed limit
Effective
Ineffective