EasyManua.ls Logo

LiteOn ISA-7 Series - Page 165

LiteOn ISA-7 Series
237 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lite-On Technology Corp.
Industrial Automation
165
PB-04
STDC
Deceleration constant of the smooth S-
curve
Communication
address:
0108H
0109H
Initial value
200
Control mode
S
Unit
ms
Configuration range
1 ~ 20000
Data size
16bit
Data format
Dec
Constant for speed acceleration: As for PB-03, PB-04 and PB-05, the time required for
acceleration from 0 to 3000r/min can be set separately.
NOTE 1) If the source of the speed command is an analog source or PB-05 is set to 0, turn off the
smooth function for S-shaped acceleration-deceleration.
PB-05
STL
Smooth constant of the smooth S-curve
Communication
address:
010AH
010BH
Initial value
0
Control mode
S
Unit
ms
Configuration range
0 ~ 10000
Data size
16bit
Data format
Dec
PB-03: It is used to set the acceleration time for trapezoidal speed command.
PB-04: It is used to set the deceleration time for trapezoidal speed command.
PB-05: It is used to set the smooth time of the S-shaped acceleration-deceleration.
PB-03, PB-04 and PB-05 can be set separately.
NOTE 1) If the source of the speed command is an analog source or PB-05 is set to 0, turn off the
smooth function for S-shaped acceleration-deceleration.
Speed command

Table of Contents