EasyManua.ls Logo

LiteOn ISA-7 Series - Chapter 10 Specifications; 10.1. Standard specification for the servo drive

LiteOn ISA-7 Series
237 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lite-On Technology Corp.
Industrial Automation
208
Chapter 10 Specifications
10.1. Standard specification for the servo drive
Model name of servo drive: ISA-7
100W
200W
400W
750W
1kW
1.5kW
2.0kW
010
020
040
075
100
150
200
Output
power
Rated voltage (Note 1)
Three phase 170VAC
Rated current [A] (Note
1)
0.9
1.7
2.8
5.8
6.0
10.0
11.0
Power supply input
of the main circuit
Voltage/frequency
Three phase AC 200 ~ 230V/50, 60Hz
Single phase AC 230V/50, 60Hz
Three phase 200VAC-230VAC,
50/60Hz
Rated current [A]
(Note 1)
0.7
1.5
2.6
3.8
5.0
8.0
10.5
Allowable voltage
variation
Three phase: 170 ~ 255 VAC
Single phase: 200 ~ 255 VAC
Three phase: 170 ~ 255 VAC
Allowable
frequency
variation
Maximum 5%
Power supply input
of the control
circuit
Voltage/frequency
Single phase 200VAC-240VAC, 50/60Hz
Rated current [A]
0.2
Allowable voltage
variation
Single phase 170VAC-255VAC
Allowable
frequency
variation
Maximum 5%
Power
consumption [W]
30
Power supply for interface
24VDC 10% (required current capacity: 0.5A)
Method for control of main circuit
Space-vector PWM control/current control method
Built-in regenerative resistor
Allowable regenerative power [W]
--
--
60
60
60
100
100
Dynamic brake
Built-in
Communication function
RS232/RS485
Output pulse of encoder
Compatible (A/B/Z-phase pulse)
Analog monitoring
Two channels are available. Use the parameter to set the monitoring signal (range of output voltage: 8V).
External control method
Pulse and analog signals
Position control
mode
Pulse frequency
of maximum
output
500k/4Mpulses/s (if the differential receiver is used) and 200kpulse/s (if the open collector is used)
Command pulse
mode
Pulse +symbol; A phase + B phase; CCW pulse + CW pulse
Command control
method
External pulse control
Command
smoothing
method
Low-pass and P-curve smoothing filter
Position feedback
pulse
Encoder resolution: 20 bits
Command pulse
rate
A/B rate of electronic gear, A: 1-16777215, B: 1-16777215, 1/10 < A/B < 4000
Width setting for
positioning
completion
0-65535 pulses (command pulse unit)
Excessive error
± 10 rotation
Torque limit
Via the parameter or external analog input (0- +10 VDC/maximum torque)
Feed-forward
compensation
Parameter setting method
Speed control
mode
Speed control
range
Analog speed command 1:2000, internal speed command 1:5000
Bandwidth
Maximum 550Hz
Command control
method
Control of external analog command/control of internal register
Command
smoothing
method
Low-pass smoothing filter; S-curve smoothing filter
Input of analog
speed command
0- 10VDC/rated speed (may be changed via the parameter at 10V speed) (Input resistance: 10kΩ-12 kΩ)
Speed variation
ratio
Maximum 0.01% (load variation ratio: 0-100%), 0% (power variation ratio: 10%)
Maximum 0.2% (ambient temperature: 25°C 10°C); then the analog speed command is used
Torque limit
Via the parameter or external analog input (0- +10 VDC/maximum torque)
Torque control
Command control
Control of external analog command

Table of Contents