Parameter
Abbr.
Function
Initial
value
Unit
Control mode
Remark
P
S
T
PD-44
RegMisc1
The write-in of the special parameter
0
O
O
O
(S-off)
(N-keep)
PD-45
RES
The value of the regenerative resistor
Based on the
model
ohm
O
O
O
PD-46
RESC
The capacity of the regenerative resistor
Based on the
model
watt
O
O
O
PD-47
CRSR
The collision protection for the motor
(torque percentage)
%
PD-48
CRST
The collision protection for the motor
(protection time)
ms
PD-49
EXREG
The selection of the external braking unit
0
N/A
O
O
O
PD-50
AUTS
The status of inertia adjustment in the
semi-auto mode
0
N/A
O
O
O
(N-keep)
PD-51
INH
The auxiliary function
0
N/A
O
O
O
PD-52
PLOSS
The detection of the input phase failure
1
O
O
O
PD-53
OSPW
The condition for the overspeed warning
max. speed
rpm
O
PD-54
PCF
The condition for giving warnings of the
excessive error regarding the position
control
480000
pulse
O
PD-55
LVF
The level for the error of the low voltage
160
V(rms)
O
O
O
PD-56
ENCType
PD-57
INFOS
PD-58
ABSRST
PD-59
AENCSTS
PD-60
APREV
PD-61
APREV
PD-62
ZPWID